Skip to main content
Log in

Inverse tracking of an airborne pollutant source location in a residential apartment by joint simulation of CFD and a multizone model

  • Research Article
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

Prompt identification of an indoor air pollutant source location is important for the safety of building residents in gaseous contaminant leakage incidents. Using the computational fluid dynamics (CFD) method in such inverse modeling is time consuming, especially for naturally ventilated residential buildings, which have multiple rooms and require consideration both indoor and outdoor environments. This paper compares the results of the pollutant source location identification and the simulation time based on two different inverse modeling methods: the CFD method and joint modeling of the multizone and CFD methods, to discuss the consumption of the computing time, as well as the accuracy of the location identification result. An instantaneous airborne pollutant source is assumed in a typical residential apartment that utilizes natural ventilation. A CFD model with the computational domain of the whole apartment and surrounding environment is built, for which the adjoint probability method is applied to simulate the source location probability from limited sensor readings. Meanwhile, a multizone model of the apartment is built to simulate and identify the room in which the source is located using the adjoint probability method. The CFD method is applied to the identified room afterwards to identify the exact location of the source within that room. The joint simulation of CFD and the multizone model is verified by a scaled model experiment of the apartment. It is found that the joint simulation method can significantly reduce the computing time and provides a good alternative for real-time inverse tracking of the indoor airborne pollutant.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Cai H, Li X, Chen Z, Wang M (2014). Rapid identification of multiple constantly-released contaminant sources in indoor environments with unknown release time. Building and Environment, 81: 7–19.

    Article  Google Scholar 

  • Chen Y, Wen J (2010). Comparison of sensor systems designed using multizone, zonal, and CFD data for protection of indoor environments. Building and Environment, 45: 1061–1071.

    Article  Google Scholar 

  • Cornacchiulo D, Bagtzoglou AC, Atmadja J (2002). Hydrologic inverse on using marching-jury backward beam equation and quasi reversibility methods. In: Proceedings of the 15th ASCE Engineering Mechanics Conference, New York, USA.

    Google Scholar 

  • Eliades DC, Michaelides MP, Panayiotou CG, Polycarpou MM (2013). Security-oriented sensor placement in intelligent buildings. Building and Environment, 63: 114–121.

    Article  Google Scholar 

  • Ferry M (2002). New features of MIGAL solver. In: Proceedings of the International PHOENICS Users Conference, Luxembourg.

    Google Scholar 

  • Gao Y, Chen Q (2003). Coupling of a multi-zone airflow analysis program with a computational fluid dynamics program for indoor air quality studies. In: Proceedings of the 4th International Symposium on HVAC, Beijing, China.

    Google Scholar 

  • Indian Standard (1987). IS: 875 (Part-3), Code of Practice for the Design Loads (other than earthquake) for Buildings and Structures—Wind Loads. New Delhi: Bureau of Indian Standards.

    Google Scholar 

  • Klepeis NE, Nelson WC, Ott WR, Robinson JP, Tsang AM, Switzer P, Behar JV, Hern SC, Engelmann WH (2001). The National Human Activity Pattern Survey (NHAPS): A resource for assessing exposure to environmental pollutants. Journal Exposure of Exposure Science & Environmental Epidemiology, 11: 231–252.

    Article  Google Scholar 

  • Li X, Chen J (2008). Evolution of contaminant distribution at steady airflow field with an arbitrary initial condition in ventilated space. Atmospheric Environment, 42: 6775–6784.

    Article  Google Scholar 

  • Li X, Shao X, Ma X, Zhang Y, Cai H (2011). A numerical method to determine the steady state distribution of passive contaminant in generic ventilation systems. Journal of Hazardous Materials, 192: 139–149.

    Google Scholar 

  • Lin R (2003). Identification of groundwater contamination sources using probabilities conditioned on measured concentrations. PhD Thesis, University of Virginia, USA.

    Google Scholar 

  • Liu X, Zhai Z (2007). Inverse modeling methods for indoor airborne pollutant tracking: literature review and fundamentals. Indoor Air, 17: 419–438.

    Article  Google Scholar 

  • Liu X (2008). Identification of indoor airborne contaminant sources with probability-based inverse modeling methods. PhD Thesis, University of Colorado, USA.

    Google Scholar 

  • Liu X, Zhai Z (2008). Location identification for indoor instantaneous point contaminant source by probability-based inverse Computational Fluid Dynamics modeling. Indoor Air, 18: 2–11.

    Article  Google Scholar 

  • Liu X, Zhai Z (2009). Protecting a whole building from critical indoor contamination with optimal sensor network design and source identification methods. Building and Environment, 44: 2276–2283.

    Article  Google Scholar 

  • Mahar PS, Datta B (2000). Identification of pollution sources in transient groundwater systems. Water Resources Management, 14: 209–227.

    Article  Google Scholar 

  • Neupauer RM, Wilson JL (1999). Adjoint method for obtaining backward-in-time location and travel time probabilities of a conservative groundwater contaminant. Water Resources Research, 35: 3389–3398.

    Article  Google Scholar 

  • Neupauer RM, Wilson JL (2001). Adjoint-derived location and travel time probabilities for a multidimensional groundwater system. Water Resources Research, 37: 1657–1668.

    Article  Google Scholar 

  • Neupauer RM, Wilson JL (2002). Backward probabilistic model of groundwater contamination in non-uniform and transient flow. Advances in Water Resources, 25: 733–746.

    Article  Google Scholar 

  • Shao X, Li X, Ma H (2016). Identification of constant contaminant sources in a test chamber with real sensors. Indoor and Built Environment, 25: 997–1010.

    Article  Google Scholar 

  • Shao X, Wang K, Li X (2019). Rapid prediction of the transient effect of the initial contaminant condition using a limited number of sensors. Indoor and Built Environment, 28: 322–334.

    Article  Google Scholar 

  • Spalding DB (1972). A novel finite difference formulation for differential expressions involving both first and second derivatives. International Journal for Numerical Methods in Engineering, 4: 551–559.

    Article  Google Scholar 

  • Vukovic V, Srebric J (2007). Application of neural networks trained with multizone models for fast detection of pollutant source position in buildings. ASHRAE Transactions, 113(2): 154–162.

    Google Scholar 

  • Wallace L (1996). Indoor particles: A review. Journal of the Air & Waste Management Association, 46: 98–126.

    Article  Google Scholar 

  • Wang L, Dols WS, Chen Q (2010). Using CFD capabilities of CONTAM 3.0 for simulating airflow and contaminant transport in and around buildings. HVAC&R Research, 16: 749–763.

    Article  Google Scholar 

  • Wang H, Lu S, Cheng J, Zhai Z (2017). Inverse modeling of indoor instantaneous airborne contaminant source location with adjoint probability-based method under dynamic airflow field. Building and Environment, 117: 178–190.

    Article  Google Scholar 

  • Wang J, Zhang T, Wang S, Battaglia F (2018). Numerical investigation of single-sided natural ventilation driven by buoyancy and wind through variable window configurations. Energy and Buildings, 168: 147–164.

    Article  Google Scholar 

  • Wei Y, Zhou H, Zhang T, Wang S (2017). Inverse identification of multiple temporal sources releasing the same tracer gaseous pollutant. Building and Environment, 118: 184–195.

    Article  Google Scholar 

  • Yee E (2012). Probability theory as logic: Data assimilation for multiple source reconstruction. Pure and Applied Geophysics, 169: 499–517.

    Article  Google Scholar 

  • Zeng L, Gao J, Du B, Zhang R, Zhang X (2018). Probability-based inverse characterization of the instantaneous pollutant source within a ventilation system. Building and Environment, 143: 378–389.

    Article  Google Scholar 

  • Zhai Z, Liu X, Wang H, Li Y, Liu J (2012). Experimental verification of tracking algorithm for dynamically-releasing single indoor contaminant. Building Simulation, 5: 5–14.

    Article  Google Scholar 

  • Zhai Z, Liu X (2017). Sensitivity analysis of the probability-based inverse modeling method for indoor contaminant tracking. International Journal of Low-Carbon Technologies, 12: 75–83.

    Google Scholar 

  • Zhang T, Chen Q (2007). Identification of contaminant sources in enclosed spaces by a single sensor. Indoor Air, 17: 439–449.

    Article  Google Scholar 

  • Zhang Z, Zhang W, Zhai ZJ, Chen QY (2007). Evaluation of various turbulence models in predicting airflow and turbulence in enclosed environments by CFD: Part 2—Comparison with experimental data from literature. HVAC&R Research, 13: 871–886.

    Article  Google Scholar 

  • Zhang T, Li H, Wang S (2012). Inversely tracking indoor airborne particles to locate their release sources. Atmospheric Environment, 55: 328–338.

    Article  Google Scholar 

  • Zhang T, Yin S, Wang S (2013). An inverse method based on CFD to quantify the temporal release rate of a continuously released pollutant source. Atmospheric Environment, 77: 62–77.

    Article  Google Scholar 

Download references

Acknowledgements

This work is financially supported by National Science Foundation of China (NSFC) (No. 51508326).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Haidong Wang.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hu, Y., Wang, H., Cheng, J. et al. Inverse tracking of an airborne pollutant source location in a residential apartment by joint simulation of CFD and a multizone model. Build. Simul. 12, 605–616 (2019). https://doi.org/10.1007/s12273-019-0547-z

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-019-0547-z

Keywords