IEICE Transactions on Electronics
Online ISSN : 1745-1353
Print ISSN : 0916-8524
Special Section on Recent Progress in Electromagnetic Theory and Its Application
Time-Domain Eddy Current and Wake Fields Analysis of Pulsed Multipole Magnet Beam Injector in Synchrotron Radiation Ring
Hideki KAWAGUCHITakumi MURAMATSUMasahiro KATOHMasahito HOSAKAYoshifumi TAKASHIMA
Author information
JOURNAL RESTRICTED ACCESS

2022 Volume E105.C Issue 4 Pages 146-153

Details
Abstract

To achieve smooth beam injection in operation of synchrotron radiation facilities, pulsed multipole magnet beam injectors are developed. It is found that the developed beam injector causes serious disturbance in the circulating storage beam in the Aichi synchrotron radiation center, and that such the unexpected disturbance of the storage beam may be caused by eddy current induced on thin titanium coating inside a beam duct. In this work, the induced eddy current on the titanium layer is evaluated quantitatively by numerical simulations and improvement for the developed beam injector is discussed based on the numerical simulation.

Content from these authors
© 2022 The Institute of Electronics, Information and Communication Engineers