Abstract
This paper investigates the application of the shift-variant data loss (SVDL) model in image quality assessment for a state-of-theart reconstruction technique, the weighted total variation (wTV), in limited angle tomography. The SVDL model is used to analyze the acquired frequency information in 2D fan-beam limited angle tomography. The wTV algorithm is applied to reconstruct some specific mathematical phantoms. The experiments show that the reconstructed image quality depends on the relation of the source trajectory and geometric structure of the imaged object, position, shape, size and orientation in particular.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Bartolac S, Clackdoyle R, Noo F, et al. A local shift-variant fourier model and experimental validation of circular cone-beam computed tomography artifacts. Med Phys. 2009;36(2):500–12.
Ritschl L, Bergner F, Fleischmann C, et al. Improved total variation-based CT image reconstruction applied to clinical data. Phys Med Biol. 2011;56(6):1545–61.
Sidky EY, Pan X. Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization. Med Phys. 2008;53(17):4777–807.
Chen Z, Jin X, Li L, et al. A limited-angle CT reconstruction method based on anisotropic TV minimization. Phys Med Biol. 2013;58(7):2119–41.
Wu H, Maier A, Fahrig R, et al. Spatial-temporal total variation regularization (STTVR) for 4D-CT reconstruction. Proc SPIE. 2012;8313.
Sidky EY, Kao CM, Pan X., Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT. J, Xray Sci Technol. 2006;14:119–39.
Candès EJ, Wakin MB, Boyd SP. Enhangcing sparsity by reweighted l1 minimization. J Fourier Anal Appl. 2008;14:877–905.
Maier A, Hofmann H, Berger M, et al. CONRAD: a software framework for conebeam imaging in radiology. Med Phys. 2013;40(11):111914.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2016 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Huang, Y. et al. (2016). Image Quality Analysis of Limited Angle Tomography Using the Shift-Variant Data Loss Model. In: Tolxdorff, T., Deserno, T., Handels, H., Meinzer, HP. (eds) Bildverarbeitung für die Medizin 2016. Informatik aktuell. Springer Vieweg, Berlin, Heidelberg. https://doi.org/10.1007/978-3-662-49465-3_49
Download citation
DOI: https://doi.org/10.1007/978-3-662-49465-3_49
Publisher Name: Springer Vieweg, Berlin, Heidelberg
Print ISBN: 978-3-662-49464-6
Online ISBN: 978-3-662-49465-3
eBook Packages: Computer Science and Engineering (German Language)